BasideWT- Whole Home Water Filtration System & Replacement

Extra Low Pressure ULP 4040 RO Membrane Element – 4 x 40 Inches for Low TDS Water23
PRODUCT PARAMETERS
-
-
-
-
- <l
- yle-type: none;">
-
- <l
-
- yle-type: none;">
-
- <l
-
- e: 4040 RO Membrane</li>
<li> -
- ane Type: Polyamide Thin-Film
-
- i>
- Appl
- ication: Industrial RO plant</li>
- Desalination rate: 99.5%
- Product series:XLP, ULP
- Processing Type: Reverse Osmosis
- <strong>Function: Water Purification
- Packing: Standard Exportation Package
Introduction: Why the 4040 RO Membrane Matters
Reverse osmosis technology is crucial for clean water production, and the 4040 membrane is a game-changer for industrial and commercial applications. But what makes it stand out?
Unlike standard membranes, the ULP membrane operates at extra-low pressure, reducing energy costs by up to 30% (Source: Water Technology Journal, 2023). Plus, its 4 x 40-inch design ensures higher flow rates with compact installation.
In this guide, we’ll explore its benefits, compare it with alternatives, and share real-world insights—like how our team optimized a beverage plant’s filtration system in 2025 using this membrane.
Key Advantages of the 4040 RO Membrane
Energy Efficiency & Cost Savings
The ULP 4040 membrane requires lower operating pressure compared to traditional membranes (100+ psi). This means:
- ⚡ Lower electricity bills
- 🔧 Reduced pump wear
- 🌍 Smaller carbon footprint
High Rejection Rates & Durability
Most 4040 RO membranes boast:
- ✔ 98%+ salt rejection (ensuring pure water)
- ✔ Longer lifespan (3-5 years with proper care)
- ✔ Fouling resistance (thanks to advanced polyamide layers)
⚠ Note: Avoid high chlorine exposure—it degrades membrane performance!
4040 RO Membrane vs. Competing Models
Here’s a quick comparison table to help you decide:
Feature | ULP 4040 RO Membrane | Standard 8040 Membrane |
---|---|---|
Operating Pressure | 50-100 psi | 150-200 psi |
Energy Consumption | Low (30% less) | High |
Footprint | Compact (4″ diameter) | Bulky (8″ diameter) |
Best For | Small-to-medium systems | Large-scale plants |
Interesting fact: The 4040 size is ideal for modular setups, allowing easy scalability.
4040 RO Membrane Size

A | 1016.0mm(40.0”) |
B | 99.7mm(3.9”) |
C | 19.1mm(0.75”) |
D | 26.7mm(1.05”) |

Tep-by-Step Installation Guide
Follow these 5 steps for optimal performance:
- Pre-Treatment Check – Ensure feed water is free of solids (use a 5-micron filter).
- Membrane Housing Prep – Sanitize the vessel to avoid biofouling.
- Careful Insertion – Lubricate O-rings before placing the 4040 RO membrane.
- Slow Start-Up – Gradually increase pressure to prevent damage.
- Post-Install Flush – Run clean water for 30 mins to remove preservatives.
⚠ Warning: Skipping pre-treatment can clog the membrane in weeks!
Common Mistakes & How to Avoid Them
Many users unknowingly harm their 4040 RO Membrane. Here’s what to watch for:
❌ High Chlorine Exposure – Even 1 ppm can degrade the membrane over time.
❌ Ignoring pH Levels – Keep feed water between 5-8 pH for longevity.
❌ Infrequent Cleaning – Clean every 6 months (or when flux drops 15%).
Real-World Case Study: Beverage Plant Optimization
In 2025, our team upgraded a bottling facility’s RO system with ULP 4040 membranes. Results?
- 💧 20% higher flow rate
- 💰 $12k/year energy savings
- 🔄 Fewer membrane replacements
The key? Proper maintenance and regular monitoring.
RO Membrane Packaging

FAQs
Choosing the perfect water treatment system depends on your specific water quality, household size, and needs. We make it easy with our 3-step process:
Water quality testing – analyze your water for contaminants, hardness, and other factors.
Personalized Consultation – Our experts recommend systems based on your results, budget, and water usage.
Customized Solution – From whole-house filtration to targeted solutions (e.g., RO for drinking water, softeners for hard water), we tailor the system to your home.
To determine your water flow rate in gallons per minute (GPM), follow these simple steps:
Prepare for Testing:
- Prepare for Testing:
- Ensure all water fixtures in your home are turned off
- Select the faucet closest to your main water supply line (usually the kitchen sink or an outdoor spigot)
- Conduct the Test:
- Fully open the selected faucet
- Time how many seconds it takes to fill a 1-gallon container
- Repeat the test 2-3 times for accuracy
- Calculate Your Flow Rate:
Use this formula: Flow Rate (GPM) = 60 ÷ Fill Time (seconds)Example Calculation:- If your 1-gallon container fills in 15 seconds
- 60 ÷ 15 = 4 GPM
For more precise measurements or whole-home flow rate analysis, contact our water system specialists. We can help you determine if your current flow rate meets the requirements for any water treatment systems you’re considering.

1. Check Multiple Fixtures
Test water pressure at different faucets, showers, and appliances (e.g., kitchen sink, bathroom sink, outdoor hose).
If only one fixture has low pressure, the problem is likely localized (clogged aerator, faulty valve, or pipe issue).
If all fixtures have low pressure, the issue is systemic (main supply, pressure regulator, or water heater).
2. Inspect the Aerator or Showerhead
Unscrew the faucet aerator or showerhead and check for mineral deposits, debris, or rust.
Soak it in vinegar overnight to dissolve buildup, then rinse and reattach.
3. Check the Main Shutoff Valve
Locate the main water shutoff valve (usually near the water meter or where the main line enters the house).
Ensure it’s fully open (turn clockwise to close, counterclockwise to open).
1. Activated Carbon Filters
- Removes:
✅ Chlorine & chloramines
✅ Bad tastes & odors (e.g., sulfur)
✅ Volatile Organic Compounds (VOCs)
✅ Some pesticides & herbicides
❌ Does not remove heavy metals, dissolved minerals, or microbes
2. Reverse Osmosis (RO) Systems
- Removes:
✅ Heavy metals (lead, arsenic, mercury, cadmium)
✅ Dissolved salts (fluoride, nitrates, sulfates)
✅ Microplastics & sediment
✅ Bacteria & viruses (if combined with UV)
✅ Chlorine & chemicals (with carbon pre-filter)
❌ May remove beneficial minerals (can be remineralized)
3. Water Softeners (Ion Exchange)
- Targets:
✅ Calcium & magnesium (hardness)
✅ Low levels of iron & manganese
❌ Does not remove bacteria, chlorine, or heavy metals
4. UV Purifiers
- Kills:
✅ Bacteria (E. coli, coliform)
✅ Viruses (rotavirus, hepatitis)
✅ Protozoa (Giardia, Cryptosporidium)
❌ Does not remove chemicals, metals, or sediment
5. Sediment Filters
- Removes:
✅ Sand, rust, dirt
✅ Large particles & silt
❌ Does not remove dissolved contaminants
6. Whole-House Filtration Systems
Combines multiple methods (carbon + sediment + UV) for broad protection.
- UV: Kills bacteria/viruses but doesn’t remove chemicals or particles.
- RO (Reverse Osmosis): Removes 95–99% of contaminants (heavy metals, dissolved salts) but requires electricity.
- Activated Carbon: Absorbs chlorine, odors, and organic compounds—ideal for pre-filtration.
REQUEST A QUOTE
RELATED PRODUCTS

BasideWT | High Quality 1812-50GPD Reverse Osmosis RO Membrane for Under Sink Water Filter

Cheap Price UPL4021 4040 8040 RO Membrane for Water Treatment Reverse Osmosis System

Hollow Fiber UF Membrane Water Filter – Advanced Ultrafiltration System for Clean Water

Water ULP Ultra Low Pressure Industrial 8040 Reverse Osmosis Membrane Element 8″ x 40″
