BasideWT- Whole Home Water Filtration System & Replacement

Factory Price Drinking Water Treatment System 1000lph Commercial RO Water Filter System
PRODUCT PARAMETERS
- Product Name: Commercial RO Water Filter System
- Water production Rate: 1000L/H
- Pre Filter: PP+GAC+PP
- Core Components: RO Membrane
- Filtration process: Reverse Osmosis Filtration
- Filter Water Quality: Purified Water/pure Direct Drinking Water
- Type: Pure Water Treatment System
- Processing Type:Reverse Osmosis
- Application:Industrial / Commercial
- Usage: Water Treatment
- Packing: Standard Exportation Package
Having a trustworthy Commercial RO Water Filter System is one asset any business that relies on clean water can not do without! The BasideWT provides industrial level purity for restaurants, hotels, manufacturing plants and health care facilities. With a decade in the business, our no secrets and nothing to hide approach to product design that allows us to create something for everyone is as unique today as it ever was.
Overview of Water Purification: Commercial Advanced
What is the BasideWT Commercial RO System. It is complete and integrated reverse osmosis system for removing up to 98 percent of contaminants found in household water. Water quality remains uniform and extremely pure as impurities are stripped at the molecular level. It’s great for food service, pharmaceutical production and other applications where water quality affects results. This durable commercial RO water system guarantees that your business will never have to settle on safety and taste.
Why choose our commercial filtration system? It is an intelligent design with practical advantages.
3-Stage Filtration System
Firstly, the system utilizes a three-stage filtration process: a sediment filter removes suspended particles, an activated carbon block adsorbs residual chlorine and odors, and finally, the RO membrane filters out dissolved solids. As a result, users obtain cleaner, better-tasting water.
High-Efficiency RO Membrane
Furthermore, the high-efficiency reverse osmosis membrane, serving as the core of the system, removes over 99% of contaminants, ensuring consistently clean, refreshing, and reliable water quality.
Smart Digital Control Panel
In addition, the smart digital control panel monitors operational status, water purity, and filter life in real time, making management and maintenance simple and intuitive.
Energy-Saving Construction
Finally, the integrated pump and flow path design enhances water flow efficiency, which not only maintains high throughput but also reduces energy consumption, thereby lowering long-term operational costs.
Technical Specifications
Below are the standard specifications for our 1000 LPH model. Custom configurations are available.
| Parameter | Specification |
|---|---|
| Model | BasideWT-RO-1000L |
| Rated Capacity | 1000 Liters Per Hour |
| Operating Pressure | 150 PSI |
| Membrane Type | Polyamide Composite |
| Power Supply | 220V / 380V, 50/60Hz |
| Connection Size | 1″ Inlet / Outlet |



Applications and Use Cases
This adaptable system has many applications. For instance, in hospitality, it ensures spot-free water for dishwashers and clean ice for drinks. Its consistent performance is what pharmaceutical labs trust for medical rinse water. Specifically, it is perfect for:
F&B: Breweries, café and ice production.
Healthcare — Laboratory equipment and sterilization.
Application : Manufacturing: Boiler Feed Water, Product Rinsing.
Farming: Hydroponic, aquaculture nutrient solutions and animal drinking water.
It is interesting to note that many car washes also apply it for avoiding deposit spots on the vehicles.
Why BasideWT Commercial RO System for Your Business?
Choosing a water ally is ultracompetitive. BasideWT offers certified quality (ISO 9001) as well as vast experience in the field of water treatment on every project. We provide full tech support from site survey to install. And our OEM/ODM service provides integration or complete custom-made. So you wind up with a system that meets your specific needs in water quality and gallons per hour, instead of compromise units off the shelf.
Installation and Maintenance Guide
Professional installation is strongly recommended for best performance. The simple process involves anchoring to a level surface, plugging in feed and drain lines and powering the control box. Always Make Sure to Test The Pressure and Flush Before Using the First Time. For optimal performance, change pre-filters every 3-6 months. But keep in mind membrane life greatly varies (2-5 years is average) depending on your pre-treatment & feed water quality. A routine service also helps to reduce unplanned downtime.
Important Safety & Operational Notes
Your system lives and dies with proper maintenance. Always use within the recommended pressure and temperature conditions (5-45°C). To store membranes, keep them in a cool dark locati0n. The opposite is don’t get the control electronics wet or left out in severe humidity. Make sure the Unit is grounded when operating. By following these standards your investment is protected and workers are safe.
Related Commercial Water Solutions
Commercial Water Softeners:Protect your RO system with the scale and prolong life for your membrane.
UV Sterilizers: Provide additional microbial protection after passing water through a filter.
Big-Capacity Storage Tanks: Provide always-fresh purified water on demand.
Commercial RO Water Filter System – FAQ
What is a Commercial RO Water Filter?
Commercial RO Water Filter System A Commercial RO Water Filter system is a water treatment unit that uses reverse osmosis technology to purify water. It is suitable for industrial enterprises, factories, hotels and others which need a long-term supply of clean water.
What is the maximum of water that can be generated with a commercial RO system in one day?
Production capacity varies by model. Typical commercial systems are 1,000 to 10,000 liters per hour. “Customizable systems for manufacturing type of operations, which can be scaled up to cater the need of high volume or usage in hospitality.
What does a commercial reverse osmosis system remove?
It efficiently removes dissolved salts, heavy metals, bacteria, viruses, chlorine and other contaminants. Multistage clean water filtration for improved quality of drinking and cooking water.
How frequently do filters and membranes have to be changed?
Prefilters (sediment & carbin) should be changed 6-12 months. RO membranes have a limited life span of 2–4 years, depending on water quality and operation. Periodic preventive maintenance can also prolong that lifespan.
Can the system work for high TDS water sources?
Answer:Yes commercial RO plants are capable of treating high-TDS water (as high as 2000 ppm and even more with tailor made systems) For very hard feed water or for dirty water a pretreatment stage is advisable.
FAQs
Choosing the perfect water treatment system depends on your specific water quality, household size, and needs. We make it easy with our 3-step process:
Water quality testing – analyze your water for contaminants, hardness, and other factors.
Personalized Consultation – Our experts recommend systems based on your results, budget, and water usage.
Customized Solution – From whole-house filtration to targeted solutions (e.g., RO for drinking water, softeners for hard water), we tailor the system to your home.
To determine your water flow rate in gallons per minute (GPM), follow these simple steps:
Prepare for Testing:
- Prepare for Testing:
- Ensure all water fixtures in your home are turned off
- Select the faucet closest to your main water supply line (usually the kitchen sink or an outdoor spigot)
- Conduct the Test:
- Fully open the selected faucet
- Time how many seconds it takes to fill a 1-gallon container
- Repeat the test 2-3 times for accuracy
- Calculate Your Flow Rate:
Use this formula: Flow Rate (GPM) = 60 ÷ Fill Time (seconds)Example Calculation:- If your 1-gallon container fills in 15 seconds
- 60 ÷ 15 = 4 GPM
For more precise measurements or whole-home flow rate analysis, contact our water system specialists. We can help you determine if your current flow rate meets the requirements for any water treatment systems you’re considering.

1. Check Multiple Fixtures
Test water pressure at different faucets, showers, and appliances (e.g., kitchen sink, bathroom sink, outdoor hose).
If only one fixture has low pressure, the problem is likely localized (clogged aerator, faulty valve, or pipe issue).
If all fixtures have low pressure, the issue is systemic (main supply, pressure regulator, or water heater).
2. Inspect the Aerator or Showerhead
Unscrew the faucet aerator or showerhead and check for mineral deposits, debris, or rust.
Soak it in vinegar overnight to dissolve buildup, then rinse and reattach.
3. Check the Main Shutoff Valve
Locate the main water shutoff valve (usually near the water meter or where the main line enters the house).
Ensure it’s fully open (turn clockwise to close, counterclockwise to open).
1. Activated Carbon Filters
- Removes:
✅ Chlorine & chloramines
✅ Bad tastes & odors (e.g., sulfur)
✅ Volatile Organic Compounds (VOCs)
✅ Some pesticides & herbicides
❌ Does not remove heavy metals, dissolved minerals, or microbes
2. Reverse Osmosis (RO) Systems
- Removes:
✅ Heavy metals (lead, arsenic, mercury, cadmium)
✅ Dissolved salts (fluoride, nitrates, sulfates)
✅ Microplastics & sediment
✅ Bacteria & viruses (if combined with UV)
✅ Chlorine & chemicals (with carbon pre-filter)
❌ May remove beneficial minerals (can be remineralized)
3. Water Softeners (Ion Exchange)
- Targets:
✅ Calcium & magnesium (hardness)
✅ Low levels of iron & manganese
❌ Does not remove bacteria, chlorine, or heavy metals
4. UV Purifiers
- Kills:
✅ Bacteria (E. coli, coliform)
✅ Viruses (rotavirus, hepatitis)
✅ Protozoa (Giardia, Cryptosporidium)
❌ Does not remove chemicals, metals, or sediment
5. Sediment Filters
- Removes:
✅ Sand, rust, dirt
✅ Large particles & silt
❌ Does not remove dissolved contaminants
6. Whole-House Filtration Systems
Combines multiple methods (carbon + sediment + UV) for broad protection.
- UV: Kills bacteria/viruses but doesn’t remove chemicals or particles.
- RO (Reverse Osmosis): Removes 95–99% of contaminants (heavy metals, dissolved salts) but requires electricity.
- Activated Carbon: Absorbs chlorine, odors, and organic compounds—ideal for pre-filtration.
REQUEST A QUOTE
RELATED PRODUCTS

BasideWT Water Softener and Reverse Osmosis System For Commercial Water Treatment

250L/Hr Marine Water Maker for Boats | Portable Reverse Osmosis Seawater Desalinator System

High-Efficiency Marine Portable 500l/H Seawater Desalination System Marine Water Treatment Machine

BasideWT 500l/h 1000l/h Seawater Desalinator Yacht Watermaker Boat Desalination Salt Water to Drink Water RO Plant

BasideWT Boat Watermaker Brackish Water Desalination Machine Reverse Osmosis Plants for Drink Water









